How to Install the Aptos MAC-800 Microinverter: Quick Step-by-Step Overview

Notice: Intended for qualified professional installers only. Always refer to and follow the full official Aptos installation manual.

Step 1: Mounting & Securing

  1. Flange Flat on the Rail:
    • Rest the built-in mounting flange flat directly onto the racking rail.
    • Ensure the silver cover faces upward toward the PV module.
  2. Seat Both Fasteners:
    • Position both rail fasteners into the flange slots.
    • Tighten both fasteners down securely to the manufacturer’s approved torque specification.

Step 2: Electrical Connections

  1. AC Trunk Connection:
    • Ensure AC is isolated and PV modules are shaded or isolated prior to wiring.
    • Connect the AC trunk cable securely to the microinverter’s AC connector.
  2. One Module per Input (DC Connections):
    • Connect your solar panels to the dual inputs (Module A and Module B).
    • Fully latch and seat both compatible DC connectors.

Step 3: Commissioning & Verification

  1. Commission the System:
    • Complete system commissioning per manual procedures.
  2. Confirm DTU Reporting:
    • Inspect, commission, and verify connectivity with the Data Transfer Unit (DTU).
    • Confirm device reporting status in the portal/app and review any alarms or fault indicators.

Contact & Support

Website: aptossolar.com

Assistance: Reach out to your dedicated Aptos sales representative for product documentation, technical support, or system sizing guidance.